First, the reasons for the "outlet dew point of the adsorption dryer that does not meet the standard":
1. The intake air flow is too large. If the maximum flow value is exceeded and the design conditions are exceeded, the design should be based on the exhaust volume and working flow of the air compressor when configuring the adsorption dryer.
2. The intake pressure is too low
3. The intake air temperature is super high
4. The intake air is seriously saturated. There is no pretreatment to remove liquid water before the air flow enters the dryer, and liquid water pretreatment should be carried out before the compressed air enters the dryer, otherwise the adsorption capacity of the adsorbent is exceeded, and the adsorbent will lose the adsorption effect after saturation.
5. The adsorbent fails
6. The dryer is not completely regenerated
Two. Search measures
1. Check whether the dryer inlet air flow, pressure and temperature are normal
2. Check whether the drain valves of equipment such as air compressors, air storage tanks and filters in front of the dryer are normal
3. Take samples from the dryer discharge port to check whether the adsorbent is invalid
4. Measure and record the exhaust temperature of the regeneration tower (with thermal suction dryer)
Third, the solution
1. The factors of inlet air flow, pressure and temperature can only be solved by adjusting the air compressor or adding other equipment
2. Replace the drainer
3. Replace the adsorbent
4. Increase the amount of regenerated gas
5. There is a thermal dryer that can then adjust the heating temperature and adjust the heating time to meet the exhaust temperature requirements of the regeneration tower.